9/3/2020 0 Comments Baumuller Drive Fault Codes
Baumuller Reparaturwerk is certainly your partner for the fastest feasible recovery of your manufacturing capacity.Our experts are accessible around the time clock on our support line, y.g.
During this procedure we will furthermore be delighted to recommend you on hów you may be capable to prevent future problems. Our cellular service teams undertake fixes, as considerably as officially probable, on web site to reduce downtimes. During this process only real spare parts are utilized, along with substitution and exchange units mainly because good as fresh. Additionally, as component of a program relationship you can define fixed response situations and the instant accessibility of defined packages of extra parts. Baumuller accompanies yóu throughout the Iifecycle of your machines and techniques with consumer specific options. The standing of your get is supervised at all situations and any changes in the position will become indicated through the keypad. A fault will be a problem that halts the push and there are two varieties of mistake conditions. When this type of problem occurs, consumer settings can end up being set up that will instantly reboot the drive or even wait around for a predetermined amount of time and then try a restart if the mistake condition is no longer found. ![]() The lead to of the fault will have got to end up being fixed before the fault can become reset and the push started. The right after is definitely a list of the feasible fault rules of the AIlen Bradley PowerFlex 40 drive and short descriptions of the leads to. Y2 Additional Input Auxiliary insight interlock is open F3 Power Loss DC tour bus voltage will be below 85 of minimal N4 UnderVoltage DC tour bus voltage is below minimal value F5 OverVoltage DC coach voltage is definitely over maximum value N6 Motor Stalled Push is not really able to speed up motor N7 Engine Overload Internal digital overload trip N8 Heatsink Overtemp Heatsink heat exceeds arranged value F12 HW OverCurrent The get output current has exceeded the hardware current limit F13 Floor Fault A present path to floor has become detected at one or more result terminals F29 Analog Insight Reduction A signal reduction at an analog insight has occurred F33 Auto Restart Attempts Drive hit a brick wall to reset a fault and continue running N38 Phase U to Terrain A phase to terrain fault offers been discovered in this phase N39 Phase Sixth is v to Surface A phase to surface fault offers been detected in this stage Y40 Phase W to Ground A phase to terrain fault offers been recognized in this phase Y41 Stage UV Brief Excessive present has long been detected between these two result terminals F42 Phase UW Short Excessive present has happen to be detected between these two output terminals F43 Stage VW Brief Excessive present has ended up recognized between these two output terminals F48 Guidelines Defaulted Travel was told to create default ideals to EEPROM F63 SW OverCurrent Programmed present trip provides been exceeded Y64 Travel Overload Drive rating of 150 for 1 minute or 200 for 3 mere seconds exceeded F70 Strength Unit Failure has been discovered in the commute power area Y71 World wide web Reduction The conversation network offers faulted N80 SVC Autotune Autotune function has been unsuccessful or was terminated by the user Y81 Comm Loss RS485 (DSI) port has halted communicating F100 Parameter Checksum The checksum learn does not really suit the checksum determined Y122 IO Panel Fail Failure has long been detected in the travel handle and IO area. Several of the flaws detailed can be removed with minor adjustments or modifications. If the fault can not be eliminated, call on the Allen Bradley restoration experts at Precision Electronic Services, Inc. Baumuller Drive Fault Codes Download A PrintableClick here to download a printable list of these problem codes. The machine is running fine and your firm has made it in my dark book and rolodex ás my go-tó for long term maintenance.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |